Electrical Testing
At ARC Technologies, a Hexcel company, we have the unique ability to customize. Standard products may have electromagnetic interference issues caused by radio frequency that cannot be remedied with ordinary solutions.We have engineers with extensive experience in materials testing and characterization from an electromagnetic perspective. We are subject matter experts when it comes to testing permittivity and permeability. ARC’s experience with electromagnetic theory allows them to complete quality electrical testing in a timely manner.
Electrical Characterization of Materials
- Far-field reflection loss
- Insertion loss
- Complex permittivity
- Complex permeability
- Surface and volume resistivity
- Customized cavity measurements
Equipment & Services include:
NRL Arch/Free space antennae/horns
- Used for measuring far-field reflection loss, insertion loss and custom free space measurements
- Standard horns (2-18 GHz)
- High frequency horns (18-40 GHz)
- Low frequency horns (0.6-2 GHz)
Focused Beam Testing
- Used for measuring complex permittivity and permeability and for measuring reflection loss from normal to 60 degrees off-angle
- Standard horns (2-26.5 GHz)
- High frequency horns (26.5-40 GHz)
- W-band horns (75-110 GHz)
Waveguides
- Used for measuring complex permittivity and permeability and for measuring insertion loss
- 7mm Coaxial waveguide (0.5-18 GHz)
- X-band WR-90 (8.2-12.4 GHz)
- K-band WR-42 (18-26.5 GHz)
- Ka-band WR-28 (26.5-40 GHz)
4-point Probe
- Used for sheet resistance of semi-conductive and conductive materials.
For a price list of our testing services, click here.